Evergreen Engineering
 
 
Evergreen Engineering U.S.A.SpacerRussian WebsiteSpacer
 

ARC FLASH ANALYSIS
LABELING AND RISK REDUCTION SERVICES

Evergreen Engineering is a multidisciplinary firm and has long provided engineering services to some of the most notable public and private organizations within the US and abroad including Canada, Russia, and Japan. With a reputation built on superior skill, great attention to detail, exceptional service and proactive problem solving, it’s obvious why much of Evergreen’s business is repeat or referral. In addition to cutting edge engineering, Evergreen provides detailed arch flash analyses, equipment warning labels, and arc flash risk reduction services.

Arc Flash Labeling

MCC/Arc flash: Arc flash analysis

THE ARC FLASH PHENOMENON

An Arc Flash happens when either phase to ground or phase to phase conductors arc in a short circuit causing electrical equipment to explode. In a fraction of a second, temperatures can soar well beyond that of the sun’s surface. These extreme temperatures cause rapid heating of the surrounding air and create tremendous pressures, producing an arc-plasma fireball that can vaporize solid metal conductors instantly. These hazards can cause severe injury or death, and millions of dollars of damage in equipment and facility downtime.




EVERGREEN ENGINEERING SOLUTIONS
Our staff has extensive experience in electrical safety, allowing us to thoroughly evaluate electrical systems and electrical training and quickly deliver comprehensive solutions. We perform detailed arc flash safety analyses to provide correct equipment warning labels required by code, and provide strategies to minimize energy available in an arc flash event. This decreases your risk and ensures your facility meets codes and standards regulating arc flash including OSHA Standards 29 (CFR) Part 1910, NFPA Standard 70 and NFPA 70E (NCE), and IEEE.1584.

Arc flash events can cost millions of dollars in medical expenses, equipment replacement and repair. We have the tools to quickly and easily evaluate alternatives and determine optimal electrical designs to prevent and reduce the level of arc flash hazard events. Our design can effectively lower fault levels, arcing time, arc incident energy and arc blast force, thus significantly reducing your risk.

Arc Flash Studies are used to estimate incident energy exposure from potential arc sources and to identify potential hazards under arc fault conditions. Our studies combine short circuit calculations, empirical equations and protective device operating times to estimate incident energy and then determine risk levels and protective clothing requirements at typical working distances. We provide warning labels communicating this information to personnel—warning labels on hazardous equipment ensures your facility will meet standards and regulations and provides a safer work environment for your employees.


ANALYSIS & LABELS
Field data gathering of electrical equipment and documentation—where necessary we can upgrade your single line diagrams to reflect the latest conditions of the power distribution system.

Analysis of field data and evaluation of the arc flash hazards using specialized software like ESA or EDSA—for each transformer, switchboard, motor control center, or panelboard, relevant arc flash data will be calculated. Arc fault magnitude, arc flash boundaries, incident energy and the category of personal protection equipment (PPE) required at each location is provided.

Provide a comprehensive Power Study that calculates the magnitude of fault currents, voltage drops and coordination of over current protection devices, in addition to identifying arc flash hazards.

Provide warning labels indicative of hazard levels and Personal Protection Equipment (PPE) required at all equipment locations.


ENGINEERING SERVICES
  • Arc flash calculations
  • Arc flash study
  • Arc flash training and electrical safety training
  • Cost estimates for implementing the recommendations listed above
  • Recommendations for removal or lowering of hazard intensities; replacing fuses, adjusting trip settings of circuit breakers and relays, and other modifications of the power distribution equipment.
  • Short circuit analysis and coordination analysis

Clients and Experience

Contact: Phone 541-484-4771 or Email us for more information

Arc Flash Analysis Publication – Brochure

 

 
Latest News

Bioenergy / PELICE Conference & Expo

Visit Evergreen Engineering in Atlanta, Georgia from February 28 – March 2 at Booth 513 of the Bioenergy / PELICE Conference & Expo

Evergreen’s Eugene office has Moved!

After more than 26 years in the same location, Eugene-based Evergreen Engineering, Inc. has moved on to new premises at 1740 Willow Creek Circle. Our new office is located in a modern campus setting in west Eugene, with easy access to freeways and the airport. Telephone and fax numbers will remain the same.
Click for Directions

 

Evergreen is Growing!

Evergreen is seeking qualified candidates to grow our team. Please check the job postings under the careers tab for details.

 

Evergreen Engineering gets top 100 award for fastest growing companies in Oregon

Evergreen Engineering Top 100 Fastest Growing companies in Oregon

 
Home | About Us | Industries | Services | Contact Us | Site Map
Evergeen Engineering